• Influence of Surfactant Type and Amount of Water on the Characteristics of Room-Temperature Polymerized Contact Lenses
  • Seong In Heo and Hyun Mee Lee*,†

  • Angyeonjae, Masan 51266, Korea
    *Department of Optometry and Vision Science, Daegu Catholic University, Gyeongbuk 38430, Korea

  • 계면활성제 종류와 물의 양이 상온중합 콘택트렌즈의 특성에 미치는 영향
  • 허성인 · 이현미*,†

  • 안경재, *대구가톨릭대학교 안경광학과

  • Reproduction, stored in a retrieval system, or transmitted in any form of any part of this publication is permitted only by written permission from the Polymer Society of Korea.


References
  • 1. Sankaridurg, P.; Lazon, J. P.; Holden, B. The Future of Silicone Hydrogel. Eye Contact Lens, 2013,39, 125-129.
  •  
  • 2. Maulvi, F. A.; Soni, T. G.; Shah, D. O.; A Review on Therapeutic Contact Lenses for Ocular Drug Delivery. Europe PMC 2016, 23, 3017-3026.
  •  
  • 3. Tran, N. P. D.; Yang M. C. Synthesis and Characterization of Silicone Contact Lenses Based on TRIS-DMA-NVP-HEMA Hydrogels. Polymers 2019, 11, 944-956.
  •  
  • 4. Musgrave, C. S. A.; Fang, F. Contact Lens Materials: A Materials Science Perspective. Materials (Basel). 2019, 12, 261-295.
  •  
  • 5. Williams, C. G.; Malik, A. N.; Kim, T. K. Manson, P. N.; Elisseeff, J. H. Variable Cytocompatibility of Six Cell Lines with Photoinitiators Used for Polymerizing Hydrogels and Cell Encapsulation. Biomaterials. 2005, 26, 1211-1218.
  •  
  • 6. Tomal, W.; Orty, J. Water-Soluble Photoinitiators in Biomedical Applications. Polymers 2020, 12, 1073-1102.
  •  
  • 7. Bae, J. H.; Ko, N. Y.; Lee, H. M. Physical Properties of Contact Lens according to Room Temperature Polymerization Conditions. J. Korean Ophthalmic Opt. Soc. 2019, 24, 231-237.
  •  
  • 8. Heo, S. I.; Lee, H. M. Changes in Physical Properties Depending on the Type of Surfactant in the Manufacture of Energy-saving Contact Lenses, J. Korean Ophthalmic Opt. Soc. 2022, 27, 7-13.
  •  
  • 9. Guan, A.; Li, Z.; Phillips, K. S. The Effects of Non-ionic Polymeric Surfactants on the Cleaning of Biofouled Hydrogel Materials. Biofouling 2015, 31, 689-697.
  •  
  • 10. Kim, E.; Saha, M.; Ehrmann, K. Mechanical Properties of Contact Lens Materials. Eye Contact Lens, 2018, 44, 1-9.
  •  
  • 11. Judy, C.; Gamal, M. M. E. M.; Jennifer, P. C.; Raid, G. A. Phase Transition Water-in-oil Microemulsions as Ocular Drug Delivery Systems: In Vitro and In Vivo Evaluation. Int. J. Pharm. 2007, 328, 65-71.
  •  
  • 12. Chiappetta, D. A.; Sosnik, A. Poly(ethylene oxide)-poly(propylene oxide) Block Copolymer Micelles as Drug Delivery Agents: Improved Hydrosolubility, Stability and Bioavailability of Drugs. Eur. J. Pharm. Biopharm. 2007, 66, 303-317.
  •  
  • 13. Phillips, A. J.; Speedwell, L. Contact Lenses, 5th edition; Elsevier: Amsterdam, 2007; pp 225-227.
  •  
  • 14. Kim, C.-H. Detergency and Liquid Wetting/Retention Properties of Soiled Polyester/Cotton(65/35) Cloth in Nonionic Surfactant Solutions. Textile Coloration and Finishing. 2011, 23, 140-145.
  •  
  • 15. Willcox, M.; Pearce, D.; Tan, M.; Demirci, G.; Carney, F. Contact Lenses and Tear Film Interactions. Lacrimal Gland, Tear Film, and Dry Eye Syndromes 3. 2002, 879-884.
  •  
  • 16. Atala, A.; Lanza, R.; Thomson, J. A.; Nerem, R. Principles of Regenerative Medicine;Elsevier/Academic: Boston, 2008; pp 579-742.
  •  
  • 17. Keith, D.; Hong, B.; Christensen, M. A. Novel Procedure for the Extraction of Protein Deposits from Soft Hydrophilic Contact Lenses for Analysis. Curr. Eye Res. 1997, 16, 503-510.
  •  
  • 18. Castillo, E.; Koenig, J.; Andersen, J.; Lo, J. Characterization of Protein Adsorption on Soft Contact Lenses: I. Conformational Changes of Adsorbed Human Serum Albumin. Biomaterials 1984, 5, 319-325.
  •  
  • 19. Soltys-Robitaille, C. E.; Ammon, D. M.; Valint, P. L.; Grobe Iii, G. L. The Relationship between Contact Lens Surface Charge and In Vitro Protein Deposition Levels. Biomaterials 2001, 22, 3257-3260.
  •  
  • Polymer(Korea) 폴리머
  • Frequency : Bimonthly(odd)
    ISSN 2234-8077(Online)
    Abbr. Polym. Korea
  • 2024 Impact Factor : 0.6
  • Indexed in SCIE

This Article

  • 2026; 50(2): 261-267

    Published online Mar 25, 2026

  • 10.7317/pk.2026.50.2.261
  • Received on Sep 1, 2025
  • Revised on Nov 25, 2025
  • Accepted on Nov 28, 2025

Correspondence to

  • Hyun Mee Lee
  • *Department of Optometry and Vision Science, Daegu Catholic University, Gyeongbuk 38430, Korea

  • E-mail: hmlee@cu.ac.kr